    <legend id="bgfcb"><hgroup id="bgfcb"><select id="bgfcb"><sup id="bgfcb"><form id="bgfcb"><progress id="bgfcb"><td id="bgfcb"></td><video id="bgfcb"><code id="bgfcb"></code></video></progress><rp id="bgfcb"><acronym id="bgfcb"></acronym></rp><p id="bgfcb"></p></form><label id="bgfcb"><sub id="bgfcb"><progress id="bgfcb"></progress><colgroup id="bgfcb"><table id="bgfcb"><optgroup id="bgfcb"></optgroup></table><tfoot id="bgfcb"></tfoot></colgroup><map id="bgfcb"></map></sub><acronym id="bgfcb"><kbd id="bgfcb"></kbd></acronym></label><colgroup id="bgfcb"></colgroup><figure id="bgfcb"></figure><code id="bgfcb"><mark id="bgfcb"><samp id="bgfcb"><param id="bgfcb"><select id="bgfcb"></select><output id="bgfcb"></output></param></samp><object id="bgfcb"></object></mark></code></sup></select><style id="bgfcb"></style></hgroup></legend><tbody id="bgfcb"></tbody>

      <label id="bgfcb"></label>

        • <td id="bgfcb"></td>
          <i id="bgfcb"></i><colgroup id="bgfcb"></colgroup>

          金属波纹管膨胀节疲劳试验方法及要求

          2018-08-06 0

          金属波纹管膨胀节的检验分类分为型式检验及出厂检验,这两项检验的内容基本一致,区别是型式检验多了“疲劳性能试验”这一项。今天我们就来了解金属波纹管膨胀节这比较“特殊”的一项的试验方法及要求。

          根据相关标准《GB/T 12777-2008 金属波纹管膨胀节通用技术条件》第6大项中“6.7 疲劳试验”中规定,金属波纹管膨胀节疲劳试验方法及要求如下:

          1、试验应在专用的疲劳试验装置上进行,疲劳试验装置应保证能约束波纹管压力推力与位移反力,并能保证施加的轴向循环位移与波纹管轴线同轴。

          2、试验波纹管应为所有其他型式检验项目合格的波纹管,波数不少于3个。试件中其他部件的根据试验装置设计,以符合试验要求。

          3、试验介质可以自来水、压缩空气、惰性性体和油等。

          4、对于波纹管设计温度低于材料蠕变温度的膨胀节,试验温度为室温。

          5、试验压力等于设计压力,试验时压力波动值不大于试验压力的±10%。

          6、试验循环位移应为轴向位移,试验循环位移范围应等于设计轴向位移量或设计相当轴向位移量。试验循环速率应以使位移在各波纹中均匀分配所需时间确定,且应小于25mm/s。

          7、达到5.9规定的试验循环次数后,目视检查波纹管表面,结果应符合5.9的要求。

          (PS:《GB/T 12777-2008 金属波纹管膨胀节通用技术条件》第5.9要求内容:“波纹管应有符合要求的疲劳性能。圆形波纹管试验循环次数应大于设计疲劳寿命的2倍。矩形波纹管试验循环次数应大于设计疲劳寿命。波纹管在规定的试验位移循环次数内应无泄露。试验介质为水时,波纹管应无漏水的现象;试验介质为气体时,皂泡检查波纹管表面应无漏气现象。”)